ZKTeco Access Control Terminal TF1600
ZKTeco TF1600 fingerprint and card access terminal for documented low-temperature outdoor use. Review heater operation, credential limits and interface directions.
Price on request
Contact us for current availability and lead time.
Request pricing, availability and the right configuration for your project.
Overview
The ZKTeco TF1600 is a fingerprint and RFID access terminal described for outdoor use, particularly low-temperature locations. The regional manufacturer description identifies an internal heating arrangement that activates when the controller detects a temperature below its working requirement. This distinguishes the documented low-temperature role from an ordinary indoor attendance reader, although the actual installation must still follow the applicable environmental and wiring requirements.
The published capacities are 3,000 fingerprint templates,30,000 cards and 100,000 event logs. They represent different stored data, rather than a total number of people to be obtained by adding all three. TCP/IP and RS485 are the documented communication interfaces. The IP65-rated enclosure is described as resistant to dust and water ingress for the stated access application; it should not be treated as a promise of operation under immersion or every possible exposure.
The door-control arrangement provides connections for a third-party electric lock, door sensor, exit button, alarm and doorbell. These allow credential verification, physical locking and door-state monitoring to be designed together. They do not establish that the listing supplies the separate lock or alarm equipment. Choose TF1600 by the required credential population, network arrangement and conditions at the mounting point, then match those requirements to the exact supplied revision and its installation instructions. The documented cold-weather capability is specific to TF1600 and should not be transferred to the similarly shaped F16.
Applications & Use Cases
- Controller-connected credential output: The specification explicitly lists Wiegand input and output. Use the required direction and supported data format for the reader/controller arrangement; the Wiegand interface is distinct from the TCP/IP or RS485 network connection.
Product FAQs
Which card option is standard?
The published specification names EM as standard and IC-card support as optional. Match the actual card module and credential technology rather than treating all card types as supplied together.
What exact operating temperature is documented?
The cited profile lists minus 40 to 45°C. Its accompanying Fahrenheit string is inconsistent at the lower endpoint; the visible specification now retains the Celsius range and records that source error rather than copying both as equivalent.
What wall-mount footprint should be planned?
The published dimensions are 62.5 × 185 × 41.5 mm, width by height by depth. Check the mounting surface, cable route and clearance against those exact TF1600 dimensions.
Which fingerprint algorithm is named?
The profile specifies ZKFinger VX10.0 with a low-temperature-resistant sensor. That is an exact-model reference, not evidence that templates from every other algorithm generation can be transferred without validation.
What power input is specified for the terminal?
The cited profile specifies 12 V DC, 3 A. This states the device input, not the complete electrical demand of a lock, alarm and other door equipment. Size the installation supply against all components in the actual design.
Specifications
| Manufacturer | ZKTeco |
|---|---|
| Model | TF1600 |
| Fingerprint Sensor | Low Temperature Resistance |
| Algorithm Version | ZKFinger VX10.0 |
| Communication | RS485, TCP/IP |
| Fingerprint Capacity | 3000 |
| Card Capacity | 30000 |
| Log Capacity | 100000 |
| RF Card | EM(standard)/IC Card(optional) |
| Authentication | Fingerprint, Card |
| Wiegand Signal | Wiegand input&output |
| Ingress Protection Rate | IP65 |
| Operating Voltage | 12VDC 3A |
| Operating Temperature | −40°C to 45°C in cited TF1600 regional profile. Source Fahrenheit lower endpoint is inconsistent; Celsius retained. |
| Size | 62.5mm×185mm×41.5mm (W×H×D) |
Downloads
Manufacturer documents and Royal Link product sheets. Check the publisher and configuration notes for each file. PDFs open in a new tab.
| Document | Type | Size | Updated / version | Action |
|---|---|---|---|---|
| PDFTF1600 - Royal Link product sheetRoyal Link Technologies LtdSupplier catalogue specifications | Product sheet | 173 KB | 2026-10-30 | Download ↗ |