ZKTeco Swing Barrier Turnstile Saturn-S2000
ZKTeco Saturn-S2000 IP54 swing barrier. Review 1200 mm stainless motorcycle option, controller dependencies and the twelve/eighteen-sensor firmware limitation.
Price on request
Contact us for current availability and lead time.
Request pricing, availability and the right configuration for your project.
Overview
The ZKTeco Saturn-S2000 is the single-lane arrangement in the Saturn-S2000 swing-barrier family. The manufacturer distinguishes it from the S2200 unit used to extend the entrance with another lane. Its SUS304 chassis, aluminium gate column and IP54 profile differ from the SPCC/IPX4 construction of the smaller Saturn families.
A brushless DC motor and clutch provide the documented movement arrangement. Twelve infrared sensor pairs are standard, with 18 optional in the published feature profile. The September 2026 manual nevertheless says the parameter logic currently supports twelve pairs. That firmware limitation needs to be resolved for the actual eighteen-pair option rather than assuming extra hardware is fully supported by every control-board revision.
The series uses acrylic barriers for its ordinary pedestrian layout, with a documented600 mm default passage and wider options. Each cabinet measures 1500 by 180 by 1020 millimetres. Top and side indicators separately show gate status and lane availability. RFID, QR and facial arrangements require the selected reader/controller integration, and CVAccess/CVSecurity support depends on the installed access controller. The published average one-second movement describes the barrier action, rather than complete people or vehicles per minute. Specify the exact barrier material, passage width, firmware, sensor arrangement and emergency interface together for the supplied entrance system.
Applications & Use Cases
- Controlled passage for two-wheeled motorcycles: The exact S2000 family documents an optional 1200 mm wide passage with stainless-steel barriers for two-wheeled motorcycles. Match the selected barrier, opening and detection configuration; this does not establish passage for cars or transfer the vehicle application to every wide Saturn gate.
Product FAQs
Is a 900 mm acrylic opening unambiguously specified?
The datasheet narrative permits acrylic up to 900 mm and requires stainless steel beyond 900 mm, while its table says stainless is required for 900–1200 mm. The 900 mm boundary is inconsistent. Obtain the exact supplied barrier and drawing; a 1200 mm arrangement clearly requires stainless steel.
Does peak passage mode preserve the same anti-pinch behaviour?
The September 2026 manual says peak mode switches the beginning and end zones to a non-pinch mode. Tailgating and reverse-intrusion closing settings can also interact with anti-pinch behaviour. Commission those policies together rather than assuming every security setting leaves the same protection response.
Can an accepted credential leave the lane available indefinitely?
The exact manual provides a two-to 60-second passage timeout, with five seconds as the documented default, and a separate closing delay. Configure those distinct timings for the actual reader and lane workflow.
Does IP54 remove the shelter condition for outdoor installation?
No. The exact S2000 profile still specifies indoor or outdoor use if sheltered, with non-condensing humidity 5–90%. Keep those conditions alongside the protection rating rather than treating IP54 as an unrestricted exposed-site or flood-operation promise.
Can any fire-panel output be connected to the emergency input?
The exact series specification requires a voltage-free contact input. Match the actual fire-system interface and test the intended emergency opening state; a powered alarm output is not established as directly compatible merely by the presence of a fire port.
Specifications
| Manufacturer | ZKTeco |
|---|---|
| Model | Saturn-S2000 |
| Audio Indicator | Internal speaker |
| Visual Indicator | Top LED indicator: Blue=Door closed/stand by Green=Door opening Red=Door closing/alarm Side LED indicator: Green=Lane available Red=Lane unavailable |
| Lane Type | Single lane |
| Lane Width | 600~900mm (Optional) (Acrylic) Maximum 1200mm (Optional) (Stainless steel) (For two-wheeled motorcycle access) |
| Barrier Movement Type | Swing |
| Motor | DC brushless motor |
| Movement Speed | Average 1s per movement (Adjustable open/close timing) |
| Clutch | Equipped |
| Movement Accuracy | Middle |
| Lid Material | Stainless steel & Polycarbonate |
| Lid Options Authentication Methods | Streamlined under mount options: QR Code / RFID Surface mount option: Facial Authentication |
| Chassis Material | Stainless steel (SUS304) (Chassis Body) / Aluminum Alloy (Gate Column) |
| Chassis Colour | Gray (Standard) |
| Barrier Material | Acrylic standard pedestrian arrangement;1200 mm motorcycle lane requires stainless steel. Source narrative requires stainless beyond 900 mm; table says900–1200 mm. Resolve exact900 mm boundary using supplied drawing. |
| IR Sensors | 12 pairs standard;18 optional in product profile. Sep2026 manual says parameter logic currently supports12 pairs. Matching firmware for 18-pair option required. |
| Motherboard Function | System configuration, access control |
| Motherboard Communication | Fire alarm port (relay)*1, RS485 port*1 |
| Controller | Compatible with C3 / InBio Series or 3rd-party controller |
| Credential Options | Under mount RFID reader: (support model: Pro ID Series, KR Series) Under mount fingerprint reader: FR1200 / FR1500S |
| Flow Rate | Facial Authentication: 15 passengers per minute QR Code: 30 passengers per minute RFID: 35 passengers per minute |
| Accessibility | Adult, children (with care), Disability (with care) |
| Power Supply | 110V / 220V ±10% AC @50Hz/60Hz |
| Power Rating | 20VA (Standby) 40VA (Operation) |
| Fire Signal | Input for voltage free contact |
| Noise Level | Less than 60dB |
| MTTR | Less than 60 minutes |
| MCBF | 5 million |
| Weight | 100Kg (Net weight); 140Kg (Gross weight) |
| Dimension (L*W*H) | 1500*180*1020mm |
| Dimension with Packing (L*W*H) | 1580 * 340 * 1270 (mm) (2pcs) |
| Operating Temperature | -30 °C to 70 °C |
| Operating Humidity | 5% to 90% RH (Non-condensing) |
| Certifications | CE, FCC |
| Ingress Protection Rating | IP54 (water & dust proof) |
| Supported Software | ZKBio CVAccess / ZKBio CVSecurity (Depends on equipped access controller) |
| Safety Features | Voltage free contact input for fire alarm fail state automatic swing barrier open during power off |
| Security Features | Anti-tailgating, anti-pinch |
| Application Environment | Indoor / outdoor (if sheltered) |
| Site Preparation | Flat & level finished floor (base plate in options for unfinished floor) |
| Security Level | Medium |
| Emergency Mode | Support (swing barrier open automatically) |
| Packing Material | Wooden |
Downloads
Manufacturer documents and Royal Link product sheets. Check the publisher and configuration notes for each file. PDFs open in a new tab.
| Document | Type | Size | Updated / version | Action |
|---|---|---|---|---|
| PDFZK Saturn-S2000 & Saturn-S2200 User Manual 20260916ZKTeco | User manual | 6.00 MB | 2026-09-17 | Download ↗ |
| PDFSaturn-S2000 Datasheet 20251112ZKTeco | Datasheet | 4.40 MB | 2025-11-13 | Download ↗ |
Manufacturer references
Customer reviews
Your experience helps others choose the right solution.
You may also like
Explore more from this product range.





Reviews
No reviews yet
Be the first to share your experience with this product.